{"id":2776,"date":"2026-09-23T09:30:14","date_gmt":"2026-09-23T07:30:14","guid":{"rendered":"https:\/\/easyliner.eu\/ar\/?p=2776"},"modified":"2026-09-23T09:30:14","modified_gmt":"2026-09-23T07:30:14","slug":"pressure-reduction-effect-of-prosthetic-liners","status":"publish","type":"post","link":"https:\/\/easyliner.eu\/ar\/innovations\/pressure-reduction-effect-of-prosthetic-liners\/","title":{"rendered":"Pressure Reduction Effect of Prosthetic Liners"},"content":{"rendered":"<div class=\"column mcb-column mcb-item-dd63356d1 one laptop-one tablet-one mobile-one column_heading vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-dd63356d1 mcb-item-heading-inner\">\n<h3 class=\"title\">How liner selection influenced pressure distribution, pain, and walking comfort in a transfemoral amputee<\/h3>\n<\/div>\n<\/div>\n<div class=\"column mcb-column mcb-item-cae452aaa one laptop-one tablet-one mobile-one column_icon_box_2 mfn-item-inline vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-cae452aaa mcb-item-icon_box_2-inner\">\n<div class=\"mfn-icon-box mfn-icon-box-left mfn-icon-box-center\">\n<h4 class=\"icon-wrapper\"><strong style=\"font-size: 20px;\">A CLINICAL CASE EVALUATION<\/strong><\/h4>\n<\/div>\n<\/div>\n<\/div>\n<h6><strong>A CASE STUDY CONDUCTED BY:<\/strong><\/h6>\n<h6><b>TOYOKAZU TAKEUCHI, <\/b>PhD., CPO<\/h6>\n<h6><b>KEIZO YAMAMOTO<\/b>, PhD<\/h6>\n<h4 style=\"text-align: center;\"><a href=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/09\/Pressure-Reduction-Effect-of-Prosthetic-Liners-Case-Study_digital.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5663\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Download-EN.png\" alt=\"\" width=\"600\" height=\"80\" \/><\/a><\/h4>\n<div class=\"column mcb-column mcb-item-fbb04d61c three-fourth laptop-three-fourth tablet-one mobile-one column_heading vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-fbb04d61c mcb-item-heading-inner\">\n<h4 class=\"title\"><strong>The prosthetic liner plays a critical role in the relationship between the residual limb and the prosthetic socket. More than simply providing a layer between the skin and socket, the liner can directly influence pressure distribution, stability, comfort, and ultimately the quality of walking.<\/strong><\/h4>\n<\/div>\n<\/div>\n<div class=\"column mcb-column mcb-item-0981e3b94 four-fifth laptop-four-fifth tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-0981e3b94 mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<h6><strong>A recent clinical case evaluation examined this relationship in a transfemoral amputee experiencing significant pain during gait. The evaluation compared multiple liner technologies and used pressure measurements during walking to better understand how liner selection affected the forces experienced at a particularly vulnerable area of the residual limb.<\/strong><\/h6>\n<\/div>\n<\/div>\n<\/div>\n<h4><strong>THE CLINICAL CHALLENGE<\/strong><\/h4>\n<p>The patient presented with a very short transfemoral residual limb. Initially, sufficient soft tissue remained around the distal end of the limb to provide protection. Over time, however, soft tissue atrophy progressed and a distal bony prominence became increasingly pronounced.<\/p>\n<p>With each step, this prominent area repeatedly contacted the inner wall of the prosthetic socket, creating localized pressure and significant pain during walking. The discomfort had begun to negatively affect both walking comfort and function.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5607 aligncenter\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Pict3-1024x676.png\" alt=\"\" width=\"500\" height=\"330\" \/><\/p>\n<p>During limb flexion, the prominence became even more apparent, illustrating the limited soft tissue available to protect the distal region from repeated loading inside the socket. This concentrated pressure was believed to be the primary source of the patient&#8217;s pain with each step.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5608 aligncenter\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Pict4-1024x704.png\" alt=\"\" width=\"500\" height=\"344\" \/><\/p>\n<p>&nbsp;<\/p>\n<p><strong style=\"font-size: 20px;\"><span class=\"divider-addon divider-label\">INITIAL IMPROVEMENT THROUGH LINER SELECTION<\/span><\/strong><\/p>\n<div class=\"wrap mcb-wrap mcb-wrap-ypfiobgh one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-ypfiobgh mfn-module-wrapper mfn-wrapper-for-wraps\">\n<p class=\"mcb-wrap-background-overlay\">Because of the severity of the patient&#8217;s discomfort, socket modification or the addition of localized padding was initially considered. Before making those changes, however, an ALPS gel liner was introduced.<\/p>\n<\/div>\n<\/div>\n<p><strong>The patient reported a significant reduction in pain through liner selection alone \u2014 with no socket modification or added padding<\/strong>.<\/p>\n<div class=\"wrap mcb-wrap mcb-wrap-ypfiobgh one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-ypfiobgh mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"column mcb-column mcb-item-9zro51va one laptop-one tablet-one mobile-one column_heading vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-9zro51va mcb-item-heading-inner\">\n<p><strong>This observation raised an important clinical question:<\/strong>\u00a0could the pressure-distribution properties of the liner itself be responsible for the improvement? To investigate further, the patient&#8217;s experience was evaluated using instrumental measurements during gait.<\/p>\n<p>&nbsp;<\/p>\n<p><strong style=\"font-size: 20px;\"><span class=\"divider-addon divider-label\">MEASURING PRESSURE DURING WALKING<\/span><\/strong><\/p>\n<\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-kdva0x7 one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-kdva0x7 mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"column mcb-column mcb-item-iocmtvz one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-iocmtvz mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>A pressure sensor was positioned at the area where the distal bony prominence was expected to contact the socket wall. The patient then completed walking trials under normal walking conditions, with approximately 20 seconds of data recorded for each liner condition.<\/p>\n<p><strong>Three liner technologies were evaluated: a commercially available silicone liner, EasyGel, and OptiGel.<\/strong>\u00a0Pressure data were recorded throughout the gait cycle to quantify loading at the painful distal region and determine whether the patient&#8217;s perceived improvement could also be observed instrumentally.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-5605 aligncenter\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Sensor.png\" alt=\"\" width=\"400\" height=\"379\" \/><\/p>\n<p>&nbsp;<\/p>\n<div class=\"column mcb-column mcb-item-vdys51r8 one laptop-one tablet-one mobile-one column_divider_2 vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-vdys51r8 mcb-item-divider_2-inner\">\n<div class=\"mfn-divider mfn-divider-advanced mfn-divider-border mfn-divider-border-solid mfn-divider-start\">\n<h4 class=\"mfn-divider-inner\"><strong><span class=\"divider-addon divider-label\">THE RESULTS: OPTIGEL PRODUCED THE LOWEST MEASURED VALUES<\/span><\/strong><\/h4>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"column mcb-column mcb-item-qtkqdnnq one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-qtkqdnnq mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>The measurements supported what the patient had experienced clinically. The commercially available silicone liner produced the highest readings of the three liner conditions. EasyGel reduced force compared with the silicone liner, while OptiGel produced the lowest measured values during walking under the evaluated conditions.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5741\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/09\/12-12_EN.png\" alt=\"\" width=\"1000\" height=\"417\" \/>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <\/strong><\/p>\n<div class=\"column mcb-column mcb-item-qtkqdnnq one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-qtkqdnnq mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5676 size-full\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Graph_ok.png\" alt=\"\" width=\"2217\" height=\"1262\" \/><\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong style=\"font-size: 16px;\">Comparison of measured force among the commercially available silicone liner, EasyGel, and OptiGel. Each dot represents a single measurement; the diamond indicates the mean value.<\/strong><\/p>\n<div class=\"wrap mcb-wrap mcb-wrap-uo58onqe one tablet-one laptop-one mobile-one vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-uo58onqe mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"wrap mcb-wrap mcb-wrap-f8ur8zoc one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-f8ur8zoc mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"column mcb-column mcb-item-1awfv89 one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-1awfv89 mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>The instrumental findings aligned with the patient&#8217;s clinical feedback: lower loading at the painful distal region corresponded with improved comfort and reduced pain during gait. Importantly, this improvement occurred without modifying the socket or adding additional padding.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-mvrfig08 one tablet-one laptop-one mobile-one vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-mvrfig08 mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"mcb-wrap-background-overlay\"><\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-s5v9rabr one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-s5v9rabr mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"mcb-wrap-background-overlay\"><strong style=\"font-size: 20px;\"><span class=\"divider-addon divider-label\">WHAT THE EVALUATION REVEALED ABOUT LINER &#8220;FEEL&#8221;<\/span><\/strong><\/div>\n<div class=\"column mcb-column mcb-item-njzu316g one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-njzu316g mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>One of the most interesting findings from the evaluation was the relationship between how a liner feels when handled and how it performs dynamically during walking. OptiGel maintains a relatively firm and stable feel, similar to that often associated with silicone liners. EasyGel, by comparison, may feel more deformable when assessed by hand.<\/p>\n<p>Yet during gait, OptiGel demonstrated a greater ability to distribute pressure and produced lower measured values than both EasyGel and the commercially available silicone liner.<\/p>\n<div style=\"background-color: #009c96; padding: 15px 30px; margin: 20px 0; box-sizing: border-box; display: flex; align-items: center; justify-content: center; text-align: left;\"><strong style=\"color: #ffffff; font-size: 20px; line-height: 1.4; margin: 0; padding: 0; display: block;\"> CLINICAL TAKEAWAY: Tactile perception alone does not necessarily translate to better dynamic pressure management.<\/strong><\/div>\n<\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-mvrfig08 one tablet-one laptop-one mobile-one vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-mvrfig08 mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"wrap mcb-wrap mcb-wrap-f9kbxypf one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-f9kbxypf mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"column mcb-column mcb-item-tz4u7sfe one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-tz4u7sfe mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>The instrumental findings aligned with the patient&#8217;s clinical feedback: lower loading at the painful distal region corresponded with improved comfort and reduced pain during gait. Importantly, this improvement occurred without modifying the socket or adding additional padding.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-b2iohp6p one tablet-one laptop-one mobile-one vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-b2iohp6p mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"mcb-wrap-background-overlay\"><\/div>\n<div class=\"wrap mcb-wrap mcb-wrap-idec0xn one tablet-one laptop-one mobile-one mfn-nested-wrap vb-item clearfix\" data-desktop-col=\"one\" data-laptop-col=\"laptop-one\" data-tablet-col=\"tablet-one\" data-mobile-col=\"mobile-one\">\n<div class=\"mcb-wrap-inner mcb-wrap-inner-idec0xn mfn-module-wrapper mfn-wrapper-for-wraps\">\n<div class=\"mcb-wrap-background-overlay\"><strong style=\"font-size: 20px;\"><span class=\"divider-addon divider-label\">BALANCING STABILITY AND PRESSURE DISTRIBUTION<\/span><\/strong><\/div>\n<div class=\"column mcb-column mcb-item-a6tkbw8i one laptop-one tablet-one mobile-one column_column vb-item\">\n<div class=\"mcb-column-inner mfn-module-wrapper mcb-column-inner-a6tkbw8i mcb-item-column-inner\">\n<div class=\"column_attr mfn-inline-editor clearfix\">\n<p>Prosthetic liner selection can sometimes be viewed as a compromise between stability and control on one side and cushioning and pressure distribution on the other. In this evaluation, OptiGel reduced localized loading while maintaining the secure, stable feel expected from a prosthetic liner \u2014 supporting stability and control, pressure distribution, patient comfort, and walking performance.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div style=\"background-color: #009c96; padding: 15px 30px; margin: 20px 0; box-sizing: border-box; display: flex; align-items: center; justify-content: center; text-align: left;\"><strong style=\"color: #ffffff; font-size: 20px; line-height: 1.4; margin: 0; padding: 0; display: block;\"> CLINICAL TAKEAWAY:<br \/>\nThis case began with a straightforward but significant clinical problem: a patient with a very short transfemoral residual limb was experiencing pain with every step because of repeated contact between a distal bony prominence and the prosthetic socket.<br \/>\nThe patient&#8217;s initial improvement with ALPS gel liners was achieved without a socket modification or additional padding. Instrumental gait evaluation subsequently confirmed measurable differences among the liner materials, with OptiGel producing the lowest values during walking under the conditions evaluated.<br \/>\nPerhaps most importantly, the case demonstrates that stability and pressure distribution do not necessarily have to be a tradeoff. OptiGel maintained a firm, stable feel while demonstrating effective dynamic pressure distribution \u2014 a combination that may be particularly meaningful when clinicians are addressing sensitive areas, bony prominences, or other pressure-management challenges.<\/strong><\/div>\n<pre><strong>Case Evaluation Note: <\/strong>This article presents findings from an individual clinical case evaluation involving a transfemoral amputee and \r\nreflects results observed under the conditions described. Individual outcomes may vary.<\/pre>\n<h4 style=\"text-align: center;\"><a href=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/09\/Pressure-Reduction-Effect-of-Prosthetic-Liners-Case-Study_digital.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5663\" src=\"https:\/\/media.easyliner.eu\/easyliner\/uploads\/2026\/08\/Download-EN.png\" alt=\"\" width=\"600\" height=\"80\" \/><\/a><\/h4>\n<\/div>\n<div style=\"display: flex; width: 100%; justify-content: space-around; align-items: flex-start; text-align: center; margin: 35px 0;\">\n<div style=\"width: 100%; display: flex; justify-content: space-around; align-items: flex-start; gap: 20px;\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>How liner selection influenced pressure distribution, pain, and walking comfort in a transfemoral amputee A CLINICAL CASE EVALUATION A CASE [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":5623,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[213],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/posts\/2776"}],"collection":[{"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/comments?post=2776"}],"version-history":[{"count":1,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/posts\/2776\/revisions"}],"predecessor-version":[{"id":2777,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/posts\/2776\/revisions\/2777"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/media?parent=2776"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/categories?post=2776"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/easyliner.eu\/ar\/wp-json\/wp\/v2\/tags?post=2776"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}